F42 Fence Controller
ID G21950The F42 Fence Controller is designed to deliver dependable and responsive perimeter performance, making it suitable for both standalone installations and HBUS‑networked environments. HV Plus Mode provides automatic escalation capability, enabling the controller to increase its deterrent response when fence conditions require heightened security. Onboard dipswitch configuration supports straightforward setup in standalone applications, ensuring fast and uncomplicated commissioning on site.
Clear visual indicators offer immediate insight into fence health and alarm activity directly at the controller, supporting efficient monitoring and rapid assessment. A dedicated service mode, accessed using the supplied magnetic key, allows maintenance tasks to be carried out safely and effectively. LV synchronization enables multiple controllers to operate in unison, providing consistent pulse timing across larger or more complex electric fence systems.
To maintain continuous protection, smart battery management ensures secure operation in the event of AC power loss, with automated backup testing assisting routine maintenance processes. Integrated temperature monitoring and pulse control safeguard reliable performance in harsh or demanding environments. Each controller is supplied with a magnetic key and power supply, delivering a complete and ready‑to‑install solution for two‑zone perimeter applications.
Awards received
- New product award for Outdoor Perimeter Protection - 2017 Security Today New Product of the Year Awards
- Platinum Award Winner, Outdoor Perimeter Protection category - 2017 Govies Government Security Awards
See our awards page for more information.
- F41 Fence Controller
- F42 Fence Controller
Features
- Available in two models, single circuit (F31 and F41) or dual circuit (F32 and F42)
- F4 models feature HVplus mode for additional deterrent
- F-Series delivers 2.3J output per circuit (3.6J for F4 HVplus mode)
- Easy maintenance design
- Alarms for fence zone, battery missing, battery test failure, tamper, over-temperature, LV signal loss, conflicting sync masters, or service mode enabled
- Five day historic alarm retention
- Support for external power management options
- Voltage and temperature reporting
- Automatic software upgrades
- Internal temperature monitoring.
Note: Some features are only available in networked mode.
Stand-alone or networked solutions
F-Series Fence Controllers can be deployed as either stand-alone (no need for an HBUS connection) or with Command Centre (v7.40 or later) as a fully integrated networked fence controller with full capabilities. F-Series Fence Controllers are delivered in their stand-alone configuration and can easily be configured as networked fence controllers via a simple on-board switch.
Stand-alone
The stand-alone configuration is designed to integrate with a customer’s existing alarm panel using simple I/O connections. This allows the fence to be controlled with the arming and disarming of the site, using the alarm panel keypads. Configuration of the device is via internal switches, control is via input signals, monitoring is via alarms (visible on the cover display), and relay outputs is to an alarm panel or other indicator devices. Stand-alone systems may consist of an individual fence controller or multiple fence controllers which are synchronized.
Note: To avoid having multiple masters, the stand-alone unit has been designed to integrate with an existing alarm panel and to be monitored and controlled from the alarm panel keypads.
Networked – HBUS
F-Series Fence Controllers can be connected via HBUS to Command Centre, where alarm monitoring, hardware/software configuration and data reporting can all be undertaken. F-Series Fence Controllers use Gallagher’s HBUS protocol for secure communication to a Controller 6000 which communicates to the server/workstation (Command Centre) via a TCP/IP network.
Networked functionality requires Command Centre v7.40 or later.
| Fence Circuits | 2 |
| Pulse rate | 1 pulse per 1.5sec |
| Low Feel | 100% 1.0kV (500Ω)† 10% 0.4kV (500Ω) |
| Output per Circuit | 2.3/3.6 J |
| Maximum HV circuit resistance | 300 ohms |
| HV | 100% Nom 8.0kV |
| HV Dual Pulse | 10.0kV (wire to earth) |
| Max recommended fence zone length | 300 m |
| Sync options | LV/HV |
| Max contact rating | 2 A at 20V DC / AC RMS |
| Software | Command Centre v7.40 or above |
| Power supply voltage | 89 - 265V AC, 50 / 60Hz V/Hz |
| Power Consumption | 55 W |
| Aux DC Output | 12 - 15V 0.7A (re-settable fuse) V/Hz |
| Internal Backup battery | 4 |
| Protection rating | IPX4 IP |
| Max LV sync cable distance | 1.2km CAT5e/Copper, 50km Fibre km |
| Standards compliance | RCM, FCC, ROHS, CE, SANS 60335-2-76:2006 Edition 2.1, ASNZS 60335.2.76:2003 Edition 2.1 inc A1, A2, A3 IEC 60335-2-76:2002 Edition 2.2 inc A1:2006 + A2:2013Compliance and certification information is available on our support site or by contacting Gallagher |